Fluke 87V/E2 Industrial Electrician's Combo Kit
본체 + 케이스 + 리드선 + 리드봉 + 악어 클립 봉 + 자석걸이 + 온도센서
|  |
Fluke 87V/E2 Industrial Electrician Combo Kit |
AC220 SureGrip™ Alligator Clip Set
TL224 SureGrip™ Silicone Test Lead Set
|  |
DMM Temperature Probe
TPAK ToolPak, Meter Hanging Kit
|
TPAK ToolPak, Meter Hanging Kit
C35 CASE

Fluke 80 Series V Digital Multimeters
|  |
Accuracy and diagnostic functions for maximum industrial productivity
The new Fluke 87V has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.
The New 80 Series consists on the following models:
- Fluke 83 V Industrial DMM
- Fluke 87 V True RMS Industrial DMM
- Fluke 87 V/E2 Industrial Electricians Combo Kit
- Data logging DMM available
| The 80 Series V operates very similar to the classic 80 series, but with more problem solving power, safety, convenience and impact protection.
The new 80 series V are independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.

|
Fluke 80 Series V Digital Multimeters
Specifications |
Voltage DC |
Maximum Voltage: |
1000V |
Accuracy: |
Fluke 83 V: ±(0.1%+1) |
|
Fluke 87 V: ±(0.05%+1) |
Maximum Resolution: |
Fluke 83 V: 100 µV |
|
Fluke 87 V: 10 µV | |
Voltage AC |
Maximum Voltage: |
1000V |
Accuracy: |
Fluke 83 V: ±(0.5%+2) |
|
Fluke 87 V: ±(0.7%+2) True RMS |
AC Bandwidth |
Fluke 83 V: 5kHz |
|
Fluke 87 V: 20kHz* |
|
*with low pass filter; 3db @ 1kHz |
Maximum Resolution: |
0.1 mV | |
Current DC |
Maximum Amps: |
10A (20 A for 30 seconds maximum) |
Amps Accuracy: |
Fluke 83 V: ±(0.4%+2) |
|
Fluke 87 V: ±(0.2%+2) |
Maximum Resolution: |
Fluke 83 V: 0.01 mA |
|
Fluke 87 V: 0.01 µA | |
Current AC |
Maximum Amps: |
10A (20 A for 30 seconds maximum) |
Amps Accuracy: |
Fluke 83 V: ±(1.2%+2) |
|
Fluke 87 V: ±(1.0%+2) True RMS |
Maximum Resolution: |
0.1 µA | |
Resistance |
Maximum Resistance: |
50 MΩ |
Accuracy: |
Fluke 83 V: ±(0.4%+1) |
|
Fluke 87 V: ±(0.2%+1) |
Maximum Resolution: |
0.1Ω | |
Capacitance |
Maximum Capacitance |
9,999 µF |
Accuracy |
±(1%+2) |
Maximum Resolution |
0.01 nF | |
Frequency |
Maximum Frequency |
200 kHz |
Accuracy |
±(0.005%+1) |
Maximum Resolution |
0.01 Hz | |
Duty Cycle |
Maximum Duty Cycle |
99.9% |
Accuracy |
±(0.2% per khz +0.1%) |
Maximum Resolution |
0.1% | |
Temperature Measurement |
Fluke 87 V, 87 V/E: |
-200.0°C - 1090°C |
|
-328.0°F - 1994.0°F |
|
excluding probe | |
80 BK Temperature Probe |
|
-40.0°C - 260°C |
|
-40.0°F - 500°F, 2.2°C or 2% whichever is greater | |
Conductance |
Maximum Conductance |
60.00 nS |
Accuracy |
±(1.0%+10) |
Maximum Resolution |
0.01 nS | |
Diode |
Range: |
3 V |
Resolution: |
1 mV |
Accuracy: |
± (2 % + 1) | |
Duty Cycle Range |
Accuracy: |
Within ± (0.2% per kHz + 0.1 %) | | |