멀티메타/멀티메타
38XR TRUE RMS DMM
타미-존
2007. 12. 15. 23:06
Amprobe 38XR-A True-rms Digital Multimeter with Temperature
Full Size Autoranging, True RMS Multimeters

기본 악세사리
- Test leads with threaded alligator clips (TL36)
- temperature adaptor (XR-TA)
- Type K thermocouple probe(TP255)
- 9 V battery (installed)
- Magne-Grip™ Holster with magnetic hanging strap
- spare fuse
- operators manual
|
Optional Accessories
VC221B Padded Vinyl Carry Case
DL248D Deluxe Test Lead Kit
DC207C Heavy Duty Case
HV231-10A High Voltage Probe
TP254A High Temperature Probe
38-SWA RS232 Cable and Software
SPEC
38XR
Specifications |
DC Voltage |
Ranges |
1000mV,10V,100V,1000V |
Accuracy all ranges: |
± (0.25 % rdg + 5 dgt) |
Resolution |
100 µV | |
AC Voltage (45 Hz to 2 kHz) True RMS |
Ranges |
1000 mV, 10 V, 100 V, 750 V |
Accuracy 750 V range: |
45 to 1 kHz: ± (2.0 % rdg + 10 dgts) |
Accuracy All other ranges, 45 to 500 Hz: |
± (1.2 % rdg + 10 dgts) |
Accuracy All other ranges, 500 to 2 kHz: |
± (2.0 % rdg + 10 dgts) |
AC coupled |
True RMS specified from 5% to 100 % of range | |
AC + DC Voltage (45 Hz to 2 kHz) |
Ranges |
1000 mV, 10 V, 100 V, 750 V |
Accuracy 750 V range:45 to 1 kHz: |
± (2.5 % rdg + 10 dgts) |
Accuracy All other ranges, 45 to 500 Hz: |
± (1.5 % rdg + 10 dgts) |
Accuracy All other ranges, 500 to 2 kHz: |
± (2.5 % rdg + 10 dgts) |
Resolution |
100 µV |
DC coupled |
True RMS specified from 5 % to 100 % of range | |
DC Current |
Ranges |
100 µA, 1000 uA, 10 mA, 100 mA, 400 mA, 10 A |
Accuracy 100 µA range: |
± (0.5 % rdg + 10 dgt) |
Accuracy 1000 uA to 400 mA ranges: |
± (0.5 % rdg + 5 dgts) |
Accuracy 10 A range: |
±(1.5 % rdg + 10 dgt) |
Resolution |
0.01 µA | |
AC Current (True RMS) ( AC + DC) (45 Hz – 1kHz) |
Ranges |
100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
Accuracy 100 µA to 100 mA ranges: |
± (1.5 % rdg + 20 dgts) |
Accuracy 400 mA range: |
± (2.0 % rdg + 10 dgts) |
Accuracy 10 A range: |
± (2.5 % rdg + 20 dgts) |
Resolution |
0.01 µA |
AC coupled |
True RMS specified from 5 % to 100 % of range |
AC + DC Accuracy 100 µA to 400 mA ranges: |
± (2.0 % rdg + 20 dgts) |
AC + DC Accuracy 10 A range: |
± (3.0 % rdg + 20 dgts) |
AC + DC: |
AC coupled True RMS specified from 10 % to 100 % of range | |
Resistance |
Ranges |
1000 Ω, 10 kΩ, 100 kΩ, 1000 kΩ, 10 MΩ, 40 MΩ |
Accuracy 1000 Ω to 1000 kΩ ranges: |
± (0.5 % rdg + 8 dgts) |
Accuracy 10 MΩ range: |
± (1.0 % rdg + 10 dgts) |
Accuracy 40 MΩ range: |
± (2.0 % rdg + 10 dgts) |
Resolution |
100 mΩ | |
Capacitance |
Ranges |
40 nF, 400 nF, 4 µF, 40 µF, 400 µF |
Accuracy 40 nF, 400 µF ranges: |
± (3.0 % rdg + 10 dgts) |
Accuracy 400 nF to 40 µF ranges: |
± (3.0 % rdg + 5 dgts) |
Resolution |
0.01 nF | |
Temperature |
Ranges |
-20 °C to 1300 °C, -4 °F to 2372 °F |
Accuracy -20 °C to 10 °C: |
± (2.0 % rdg + 4 °C ) |
Accuracy 10 °C to 200 °C: |
± (1.0 % rdg + 3 °C ) |
Accuracy 200 °C to 1300 °C: |
± (2.0 % rdg + 2 °C ) |
Accuracy -4 °F to 50 °F: |
± (2.0 % rdg + 8 °F) |
Accuracy 50 °F to 400 °F: |
± (1.0 % rdg + 6 °F) |
Accuracy 400 °F to 2372 °F: |
± (2.0 % rdg + 4 °F) |
Resolution |
1 °C, 1 °F | |
Frequency |
Ranges |
100 Hz, 1000 Hz, 10 kHz, 100 kHz, 1000 kHz, 10 MHz |
Accuracy all ranges: |
± (0.1% rdg + 5 dgts)Resolution 0.01 Hz | |
Duty Cycle |
Ranges |
0 to 90 % |
Accuracy 5 V logic: |
± (2.0% rdg + 10 dgts) |
Resolution |
0.01 % |
Frequency Range 0 % to 10 %: |
40 Hz to 990 Hz |
Frequency Range 10 % to 90 %: |
40 Hz to 20 kHz | |
4 - 20 mA DC Current Test |
Range |
0 – 100 % |
Accuracy |
± (0.5 % + 5 dgts) |
Resolution |
0.01 % | |
DBm |
Ranges |
-13 dBm to + 50 dBm |
Accuracy 45 Hz to 5 kHz: |
± (0.7 dB + 8 dgts) |
Accuracy 5 kHz to 10 kHz: |
± (2.5 dB + 8 dgts) |
Resolution |
0.01 dBm | |
Continuity |
Audible Indication |
< 40 Ω | |
Diode Test |
Test Current |
0.5 mA (approximate) |
Open Circuit Volts |
3.0 V dc typical | |
Peak |
AC Volts Accuracy 100 V, 750 V ranges: |
± (3.0 + 200 dgts) |
AC Volts Accuracy 1000 mV, 10 V ranges: |
unspecified AC Current ± (3.0 + 200 dgts) | |
Overload Protection |
AC/DC Voltage |
1000 V dc or 750 V ac rms |
AC/DC Current µA/mA input: |
F0.5 A /1000 V fast-blow ceramic 6.3 x 32 mm |
AC/DC Current 10A input: |
F10 A /1000V fast-blow ceramic 10 x 38 mm | |
General Specifications |
Autoranging Display: |
|
4-3/4 digit LCD, 10,000 counts with 41-segment analog bar graph | |
Display Update Rate |
|
Power Battery |
|
9 V NEDA 1604, JIS 006P, IEC 6F22 | |
Battery Life |
|
150 hrs typical (alkaline) frequent use of backlight will decrease battery life | |
Operating Temperature |
|
0 °C to 45 °C at< 70% R.H | |
Storage Temperature |
|
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter | |
Temperature Coefficient |
|
0.1 x (specified accuracy) per °C (0 °C to 18 °C , 28 °C to 45 °C) | |
Altitude |
|
Dimensions: |
|
7.8" x 3.55" x 2.4" (196 x 96 x 60 mm) | |
Weight (without holster, includingbattery) |
|
Voltage AC |
|
Voltage DC |
|
mV AC |
|
Basic DC Accuracy |
|
DC Current, fused |
|
AC Current, fused |
|
Resistance |
|
Capacitance |
|
Frequency |
|
Temperature |
|